Imperial College London

ProfessorDominikWeiss

Faculty of EngineeringDepartment of Earth Science & Engineering

Professor of Environmental Geochemistry
 
 
 
//

Contact

 

+44 (0)20 7594 6383d.weiss

 
 
//

Location

 

2.39Royal School of MinesSouth Kensington Campus

//

Summary

 

Publications

Citation

BibTex format

@article{Araújo:2016:10.5935/0103-5053.20160167,
author = {Araújo, DF and Boaventura, GR and Viers, J and Mulholland, DS and Weiss, D and Araújo, D and Lima, B and Ruiz, I and Machado, W and Babinski, M and Dantas, E},
doi = {10.5935/0103-5053.20160167},
journal = {Journal of the Brazilian Chemical Society},
pages = {225--235},
title = {Ion exchange chromatography and mass bias correction for accurate and precise Zn isotope ratio measurements in environmental reference materials by MC-ICP-MS},
url = {http://dx.doi.org/10.5935/0103-5053.20160167},
volume = {28},
year = {2016}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - Precise and accurate δ66/64Zn data for environmental reference materials (RMs) including rocks,sediments, soils and plants are presented in order to improve the metrological traceability andanalytical control of Zn isotope ratio determinations in future environmental studies. Previouslydeveloped ion exchange chromatography protocols were adjusted to enable faster sample throughputand instrumental mass bias processes were investigated. The improved chromatographic protocolyielded precise and quantitative recoveries (99 ± 7%, σ, n = 16), while the mass bias correctionusing Cu as external dopant provided precisions better than 0.02‰, 2σ, n = 7. Investigations intospectral and non-spectral interferences identified significant formation of Cr and Ti oxides andhydroxide ionic species. Analysis of six RMs (BHVO-2 basalt (USGS), BCR-2 basalt (USGS),AGV-2 andesite (USGS), 2709 San Joaquin soil (NIST), 1646a estuarine sediment (NIST) and1573a tomato leaves (NIST)) showed good reproducibility (< 0.01‰, 2σ, 5 ≤ n ≥ 1).
AU - Araújo,DF
AU - Boaventura,GR
AU - Viers,J
AU - Mulholland,DS
AU - Weiss,D
AU - Araújo,D
AU - Lima,B
AU - Ruiz,I
AU - Machado,W
AU - Babinski,M
AU - Dantas,E
DO - 10.5935/0103-5053.20160167
EP - 235
PY - 2016///
SN - 0103-5053
SP - 225
TI - Ion exchange chromatography and mass bias correction for accurate and precise Zn isotope ratio measurements in environmental reference materials by MC-ICP-MS
T2 - Journal of the Brazilian Chemical Society
UR - http://dx.doi.org/10.5935/0103-5053.20160167
UR - http://hdl.handle.net/10044/1/42831
VL - 28
ER -