@inproceedings{Pavia:2016,
author = {Pavia, JP and Otter, WJ and Lucyszyn, S and Ribeiro, MA},
title = {Design of a THz-MEMS frequency selective surface for structural health monitoring},
url = {http://hdl.handle.net/10044/1/38532},
year = {2016}
}

RIS format (EndNote, RefMan)

TY  - CPAPER
AB - This paper characterizes the relationship between applied force and reflectance/transmittance of a terahertz frequency selective surface for use as a sensor in structural healthmonitoring. Numerical modelling of both the mechanical and electromagnetics, solving the elasticityequation and Maxwell’s equations, respectively, has been undertaken for a 3 layer device.The unit cell comprises of a metal cross wire embedded within a (hard) silicon substrate, interleavedwith stacks of (soft) low density polyethylene.
AU - Pavia,JP
AU - Otter,WJ
AU - Lucyszyn,S
AU - Ribeiro,MA
PY - 2016///
TI - Design of a THz-MEMS frequency selective surface for structural health monitoring
UR - http://hdl.handle.net/10044/1/38532