Imperial College London

Angela Kedgley

Faculty of EngineeringDepartment of Bioengineering

Senior Lecturer
 
 
 
//

Contact

 

+44 (0)20 7594 0747a.kedgley Website

 
 
//

Location

 

514BBuilding E - Sir Michael UrenWhite City Campus

//

Summary

 

Publications

Citation

BibTex format

@article{Jones:2020:10.3390/s20041123,
author = {Jones, D and Wang, L and Ghanbari, A and Vardakastani, V and Kedgley, AE and Gardiner, MD and Vincent, TL and Culmer, PR and Alazmani, A},
doi = {10.3390/s20041123},
journal = {Sensors},
pages = {1--13},
title = {Design and evaluation of magnetic hall effect tactile sensors for use in sensorized splints},
url = {http://dx.doi.org/10.3390/s20041123},
volume = {20},
year = {2020}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - Splinting techniques are widely used in medicine to inhibit the movement of arthritic joints. Studies into the effectiveness of splinting as a method of pain reduction have generally yielded positive results, however, no significant difference has been found in clinical outcomes between splinting types. Tactile sensing has shown great promise for the integration into splinting devices and may offer further information into applied forces to find the most effective methods of splinting. Hall effect-based tactile sensors are of particular interest in this application owing to their low-cost, small size, and high robustness. One complexity of the sensors is the relationship between the elastomer geometry and the measurement range. This paper investigates the design parameters of Hall effect tactile sensors for use in hand splinting. Finite element simulations are used to locate the areas in which sensitivity is high in order to optimise the deflection range of the sensor. Further simulations then investigate the mechanical response and force ranges of the elastomer layer under loading which are validated with experimental data. A 4 mm radius, 3 mm-thick sensor is identified as meeting defined sensing requirements for range and sensitivity. A prototype sensor is produced which exhibits a pressure range of 45 kPa normal and 6 kPa shear. A proof of principle prototype demonstrates how this can be integrated to form an instrumented splint with multi-axis sensing capability and has the potential to inform clinical practice for improved splinting.
AU - Jones,D
AU - Wang,L
AU - Ghanbari,A
AU - Vardakastani,V
AU - Kedgley,AE
AU - Gardiner,MD
AU - Vincent,TL
AU - Culmer,PR
AU - Alazmani,A
DO - 10.3390/s20041123
EP - 13
PY - 2020///
SN - 1424-8220
SP - 1
TI - Design and evaluation of magnetic hall effect tactile sensors for use in sensorized splints
T2 - Sensors
UR - http://dx.doi.org/10.3390/s20041123
UR - http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000522448600174&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
UR - https://www.mdpi.com/1424-8220/20/4/1123
UR - http://hdl.handle.net/10044/1/79174
VL - 20
ER -