Imperial College London

ProfessorBassamIzzuddin

Faculty of EngineeringDepartment of Civil and Environmental Engineering

Professor of Computational Structural Mechanics
 
 
 
//

Contact

 

+44 (0)20 7594 5985b.izzuddin Website

 
 
//

Assistant

 

Ms Ruth Bello +44 (0)20 7594 6040

 
//

Location

 

330Skempton BuildingSouth Kensington Campus

//

Summary

 

Publications

Citation

BibTex format

@article{Ravasini:2021:10.1016/j.engstruct.2021.113291,
author = {Ravasini, S and Sio, J and Franceschini, L and Izzuddin, BA and Belletti, B},
doi = {10.1016/j.engstruct.2021.113291},
journal = {Engineering Structures},
pages = {1--16},
title = {Validation of simplified tying force method for robustness assessment of RC framed structures},
url = {http://dx.doi.org/10.1016/j.engstruct.2021.113291},
volume = {249},
year = {2021}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - The robustness of reinforced concrete (RC) structures is an important ongoing research topic in the civil engineering community. Especially in the last decades, the need for structural robustness assessment methods has become urgent, and several design methods have been proposed in codes and guidelines to mitigate the progressive collapse risk of reinforced concrete structures. The most used approaches are the Tying Force and Alternate Load Path methods. The first is typically applied as an indirect and prescriptive method where the building is considered mechanically tied together and able to enhance continuity and the resistance to progressive collapse. The second is a direct method, where the capacity of the structure to sustain the applied loads is evaluated after the loss of a load-bearing element, most effectively using advanced nonlinear structural analysis methods. In the context of the Tying Force method, the Eurocode is recognised to underestimate the tie force demands required by building structures subject to the loss of a load bearing member, which are better reflected in the USA UFC Guidelines. A new Tying Force method has been proposed by Izzuddin & Sio (2021) for the next generation of the Eurocodes, which addresses the shortcomings of the present Eurocode guidance, and provides a more comprehensive treatment than considered in the UFC code. The present paper is aimed specifically at the validation of the new Simplified Tying Force method (Izzuddin & Sio, 2021) for reinforced concrete structures, considering grillage and combined beam/slab floor systems, and considering the rotational ductility of such structures, which is explicitly considered in the new method.
AU - Ravasini,S
AU - Sio,J
AU - Franceschini,L
AU - Izzuddin,BA
AU - Belletti,B
DO - 10.1016/j.engstruct.2021.113291
EP - 16
PY - 2021///
SN - 0141-0296
SP - 1
TI - Validation of simplified tying force method for robustness assessment of RC framed structures
T2 - Engineering Structures
UR - http://dx.doi.org/10.1016/j.engstruct.2021.113291
UR - https://www.sciencedirect.com/science/article/pii/S0141029621014115?via%3Dihub
UR - http://hdl.handle.net/10044/1/92361
VL - 249
ER -