Imperial College London

Professor Hippolite Amadi, PhD FRSM FIMechE

Faculty of EngineeringDepartment of Bioengineering

Visiting Professor
 
 
 
//

Contact

 

h.amadi Website CV

 
 
//

Location

 

Royal School of MinesSouth Kensington Campus

//

Summary

 

Publications

Citation

BibTex format

@article{Amadi:2012:10.1111/j.1469-7580.2012.01490.x,
author = {Amadi, HO and Fogg, QA and Ugbolue, UC and Emery, RJH and Bull, AMJ},
doi = {10.1111/j.1469-7580.2012.01490.x},
journal = {Journal of Anatomy},
pages = {525--528},
title = {Reliability of a set of protractors for direct anatomical measurements around the glenoid and humeral head rims},
url = {http://dx.doi.org/10.1111/j.1469-7580.2012.01490.x},
volume = {220},
year = {2012}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - Functional biomechanics studies of the glenohumeral (GH) soft tissues require an understanding of their sites of bony attachment. Anatomical positions of GH capsular structures have often been quantified relative to the rims of the glenoid and humeral head (HH). The aim of this study was twofold: (1) to quantify the reliability of a set of protractors that directly fit on to the glenoid and HH rims and (2) to use this to determine direct angular position referencing of landmarks and soft tissue attachment points. Three assessors independently used the protractors to assess nine prescribed landmarks on 30 dry bone specimens (15 glenoids and 15 HHs) recording the angular positions of the structures relative to the glenoid and HH. The collected data showed high levels of validity as indicated by the protractor’s intra and interassessor reliabilities: 98.2 and 98.7% for the glenoid component, and 96.2 and 96.5% for the humeral component, respectively. The device could be useful in anatomical studies, description of defects and pathologies on glenohumeral articulation, and planning of scapular reconstructive surgery.
AU - Amadi,HO
AU - Fogg,QA
AU - Ugbolue,UC
AU - Emery,RJH
AU - Bull,AMJ
DO - 10.1111/j.1469-7580.2012.01490.x
EP - 528
PY - 2012///
SN - 0021-8782
SP - 525
TI - Reliability of a set of protractors for direct anatomical measurements around the glenoid and humeral head rims
T2 - Journal of Anatomy
UR - http://dx.doi.org/10.1111/j.1469-7580.2012.01490.x
UR - http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000302536500010&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
UR - https://onlinelibrary.wiley.com/doi/full/10.1111/j.1469-7580.2012.01490.x
VL - 220
ER -