Imperial College London

Prof. J. P. Martin Trusler

Faculty of EngineeringDepartment of Chemical Engineering

Professor of Thermophysics
 
 
 
//

Contact

 

+44 (0)20 7594 5592m.trusler Website

 
 
//

Assistant

 

Miss Jessica Baldock +44 (0)20 7594 5699

 
//

Location

 

409ACE ExtensionSouth Kensington Campus

//

Summary

 

Publications

Citation

BibTex format

@article{Pan:2022:10.1007/s10765-022-02997-z,
author = {Pan, Z and Trusler, JPM},
doi = {10.1007/s10765-022-02997-z},
journal = {International Journal of Thermophysics},
pages = {1--14},
title = {Refractive index effects in pendant drop tensiometry},
url = {http://dx.doi.org/10.1007/s10765-022-02997-z},
volume = {43},
year = {2022}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - An optical model is established to investigate the effects of refractive index changes on the measurement of interfacial tension by the pendant drop method with axisymmetric drop shape analysis. In such measurements, light passes from the pendant drop through a surrounding bulk phase, an optical window and air to reach the lens of the camera system. The relation between object and image size is typically determined by calibration and, if the refractive indices of any of the materials in the optical path change between calibration and measurement, a correction should be made. The simple model derived in this paper allows corrections to be calculated along with the corresponding contribution to the overall uncertainty of the interfacial tension. The model was verified by measurements of the interfacial tension between decane and water under two different calibration conditions. Neglect of the correction was shown to cause errors of up to 6 % when the bulk phase changed from air (during calibration) to water (during measurements) and of about 9 % when the system was calibrated without the optical window used for the final measurements. The refraction changes due to high pressures and supercritical fluid states can also lead to measurement errors. The proposed model can facilitate more accurate interfacial tension measurements and reduce the amount of repetitive calibration work required.
AU - Pan,Z
AU - Trusler,JPM
DO - 10.1007/s10765-022-02997-z
EP - 14
PY - 2022///
SN - 0195-928X
SP - 1
TI - Refractive index effects in pendant drop tensiometry
T2 - International Journal of Thermophysics
UR - http://dx.doi.org/10.1007/s10765-022-02997-z
UR - http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000761325700001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
UR - https://link.springer.com/article/10.1007/s10765-022-02997-z
UR - http://hdl.handle.net/10044/1/98662
VL - 43
ER -