Imperial College London

DrPatrickDunne

Faculty of Natural SciencesDepartment of Physics

Lecturer (Future Leader Fellow)
 
 
 
//

Contact

 

p.dunne12

 
 
//

Location

 

531aBlackett LaboratorySouth Kensington Campus

//

Summary

 

Publications

Citation

BibTex format

@article{Jones:2020:10.3390/instruments4030021,
author = {Jones, SB and Nonnenmacher, TS and Atkin, E and Barker, GJ and Basharina-Freshville, A and Betancourt, C and Boyd, SB and Brailsford, D and Chen-Wishart, Z and Cremonesi, L and Deisting, A and Dias, A and Dunne, P and Haigh, J and Hamacher-Baumann, P and Kaboth, A and Korzenev, A and Ma, W and Mermod, P and Mironova, M and Monroe, J and Nichol, R and Nowak, J and Parker, W and Ritchie-Yates, H and Roth, S and Saakyan, R and Serra, N and Shitov, Y and Steinmann, J and Tarrant, A and Uchida, MA and Valder, S and Waldron, AV and Ward, M and Wascko, MO},
doi = {10.3390/instruments4030021},
journal = {Instruments},
pages = {21--21},
title = {Off-axis characterisation of the CERN T10 beam for low momentum proton measurements with a high pressure gas time projection chamber},
url = {http://dx.doi.org/10.3390/instruments4030021},
volume = {4},
year = {2020}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - We present studies of proton fluxes in the T10 beamline at CERN. A prototype high pressure gas time projection chamber (TPC) was exposed to the beam of protons and other particles, using the 0.8 GeV/c momentum setting in T10, in order to make cross section measurements of low energy protons in argon. To explore the energy region comparable to hadrons produced by GeV-scale neutrino interactions at oscillation experiments, i.e., near 0.1 GeV of kinetic energy, methods of moderating the T10 beam were employed: the dual technique of moderating the beam with acrylic blocks and measuring scattered protons off the beam axis was used to decrease the kinetic energy of incident protons, as well as change the proton/minimum ionising particle (MIP) composition of the incident flux. Measurements of the beam properties were made using time of flight systems upstream and downstream of the TPC. The kinetic energy of protons reaching the TPC was successfully changed from ∼0.3 GeV without moderator blocks to less than 0.1 GeV with four moderator blocks (40 cm path length). The flux of both protons and MIPs off the beam axis was increased. The ratio of protons to MIPs vary as a function of the off-axis angle allowing for possible optimisation of the detector to select the type of required particles. Simulation informed by the time of flight measurements show that with four moderator blocks placed in the beamline, (5.6 ± 0.1) protons with energies below 0.1 GeV per spill traversed the active TPC region. Measurements of the beam composition and energy are presented.
AU - Jones,SB
AU - Nonnenmacher,TS
AU - Atkin,E
AU - Barker,GJ
AU - Basharina-Freshville,A
AU - Betancourt,C
AU - Boyd,SB
AU - Brailsford,D
AU - Chen-Wishart,Z
AU - Cremonesi,L
AU - Deisting,A
AU - Dias,A
AU - Dunne,P
AU - Haigh,J
AU - Hamacher-Baumann,P
AU - Kaboth,A
AU - Korzenev,A
AU - Ma,W
AU - Mermod,P
AU - Mironova,M
AU - Monroe,J
AU - Nichol,R
AU - Nowak,J
AU - Parker,W
AU - Ritchie-Yates,H
AU - Roth,S
AU - Saakyan,R
AU - Serra,N
AU - Shitov,Y
AU - Steinmann,J
AU - Tarrant,A
AU - Uchida,MA
AU - Valder,S
AU - Waldron,AV
AU - Ward,M
AU - Wascko,MO
DO - 10.3390/instruments4030021
EP - 21
PY - 2020///
SN - 2410-390X
SP - 21
TI - Off-axis characterisation of the CERN T10 beam for low momentum proton measurements with a high pressure gas time projection chamber
T2 - Instruments
UR - http://dx.doi.org/10.3390/instruments4030021
UR - https://www.mdpi.com/2410-390X/4/3/21
UR - http://hdl.handle.net/10044/1/88863
VL - 4
ER -