Imperial College London

DrPeterGatehouse

Faculty of MedicineNational Heart & Lung Institute

Honorary Clinical Senior Lecturer
 
 
 
//

Contact

 

+44 (0)20 7351 8807p.gatehouse

 
 
//

Location

 

MRISydney StreetRoyal Brompton Campus

//

Summary

 

Publications

Publication Type
Year
to

245 results found

Vassiliou V, Heng EL, Sharma P, Nyktari E, Raphael CE, Chin CW, Drivas P, Smith GC, Symmonds K, Mathew GL, Wage R, Ali A, Greiser A, Alpendurada F, Dweck MR, Pennell DJ, Gatehouse P, Prasad SKet al., 2015, Reproducibility of T1 mapping 11-heart beat MOLLI Sequence, Journal of Cardiovascular Magnetic Resonance, Pages: 1-3, ISSN: 1097-6647

Journal article

Wage R, Patel H, Smith GC, Keegan J, Gatehouse P, Vassiliou V, Heng EL, Hayward C, Rosen SD, Lyon A, Mohiaddin R, Prasad SK, Pennell DJ, Di Mario Cet al., 2015, The utility of magnetic resonance imaging in a trial to assess the effect of renal denervation in heart failure with preserved ejection fraction, Journal of Cardiovascular Magnetic Resonance, Pages: 1-2, ISSN: 1097-6647

Journal article

Fair M, Gatehouse P, Firmin D, 2015, Through-plane dark-rim artefacts in 3D first-pass myocardial perfusion, Journal of Cardiovascular Magnetic Resonance, Vol: 17, ISSN: 1532-429X

The dark-rim artefact (DRA) is well known in 2D first-pass perfusion (FPP). The in-plane features of DRA are understood, but DRA has not been examined along the second phase-encoding (partition) direction for 3D FPP. The Gibbs contribution to DRAs in 2D FPP is minimised by finer resolution, but low through-plane resolutions of 3D FPP imply risk of partition axis DRAs. We investigated these new partition DRAs ("PDRAs") and partial volume effects due to coarse resolution of this direction.

Journal article

Vassiliou V, Heng EL, Donovan J, Greiser A, Babu-Narayan SV, Gatzoulis MA, Firmin D, Pennell DJ, Gatehouse P, Prasad SKet al., 2015, Longitudinal stability of gel T1 MRI Phantoms for quality assurance of T1 mapping, Journal of Cardiovascular Magnetic Resonance, Vol: 17, ISSN: 1532-429X

Journal article

Raphael CE, Hsu LY, Greve AM, Cooper R, Gatehouse P, Wage R, Vassiliou V, Ali A, de Silva R, Stables RH, Di Mario C, Parker KH, Pennell DJ, Arai AE, Prasad SKet al., 2015, Wave intensity analysis and assessment of myocardial perfusion abnormalities in patients with hypertrophic cardiomyopathy, Journal of Cardiovascular Magnetic Resonance, Vol: 17, ISSN: 1097-6647

Journal article

Heng EL, Kellman P, Gatzoulis MA, Moon J, Gatehouse P, Babu-Narayan SVet al., 2015, Pilot data of right ventricular myocardial T1 quantification by free-breathing fat-water separated dark blood saturation-recovery imaging, Journal of Cardiovascular Magnetic Resonance, Pages: 1-2, ISSN: 1097-6647

Journal article

Kellman P, Xue H, Spottiswoode BS, Sandino CM, Hansen MS, Abdel-Gadir A, Treibel TA, Rosmini S, Mancini C, Bandettini WP, McGill L-A, Gatehouse P, Moon JC, Pennell DJ, Arai AEet al., 2015, Free-breathing T2*mapping using respiratory motion corrected averaging, JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, Vol: 17, ISSN: 1097-6647

Journal article

Keegan J, Gatehouse PD, Haldar S, Wage R, Babu-Narayan SV, Firmin DNet al., 2015, Dynamic Inversion Time for Improved 3D Late Gadolinium Enhancement Imaging in Patients with Atrial Fibrillation, Magnetic Resonance in Medicine, Vol: 73, Pages: 646-654, ISSN: 1522-2594

Purpose—High resolution 3D late gadolinium enhancement (LGE) imaging is performed withsingle R-wave gating to minimise lengthy acquisition durations. In patients with atrial fibrillation(AF), heart rate variability results in variable magnetisation recovery between sequence repeatsand image quality is often poor. In this study, we implemented and tested a dynamic inversiontime scheme designed to reduce sequence sensitivity to heart rate variations.Methods—An inversion-prepared 3D segmented gradient echo sequence was modified so thatthe inversion time (TI) varied automatically from beat-to-beat (dynamic-TI) based on the timesince the last sequence repeat. 3D LGE acquisitions were performed in 17 patients prior to RFablation of persistent AF both with and without dynamic-TI. Qualitative image quality scores,blood signal-to-ghosting ratios (SGRs) and blood-myocardium contrast-to-ghosting ratios (CGRs)were compared.Results—Image quality scores were higher with dynamic-TI than without (2.2 +/− 0.9 versus 1.8+/− 1.1, p = 0.008) as were blood-myocardium CGRs (13.8 +/− 7.6 versus 8.3 +/− 6.1, p = 0.003)and blood SGRs (19.6 +/− 8.5 versus 13.1 +/− 8.0, p = 0.003).Conclusions—The dynamic-TI algorithm improves image quality of 3D LGE imaging in thisdifficult patient population by reducing the sequence sensitivity to RR interval variations.

Journal article

Fair M, Gatehouse P, Firmin D, 2015, Through-plane dark-rim artefacts in 3D first-pass myocardial perfusion, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, Vol: 17, ISSN: 1097-6647

Journal article

Scott AD, Ferreira PFADC, Nielles-Vallespin S, Gatehouse P, McGill L-A, Kilner P, Pennell DJ, Firmin DNet al., 2015, Optimal diffusion weighting for in vivo cardiac diffusion tensor imaging, Magnetic resonance in medicine, Vol: 74, Pages: 420-430

Journal article

McGill L-A, Scott AD, Ferreira PF, Nielles-Vallespin S, Ismail T, Kilner PJ, Gatehouse PD, de Silva R, Prasad SK, Giannakidis A, otherset al., 2015, Heterogeneity of fractional anisotropy and mean diffusivity measurements by in vivo diffusion tensor imaging in normal human hearts, PloS one, Vol: 10, Pages: e0132360-e0132360

Journal article

Ferreira PF, Kilner PJ, McGill L-A, Nielles-Vallespin S, Scott AD, Ho SY, McCarthy KP, Haba MM, Ismail TF, Gatehouse PD, otherset al., 2014, In vivo cardiovascular magnetic resonance diffusion tensor imaging shows evidence of abnormal myocardial laminar orientations and mobility in hypertrophic cardiomyopathy, Journal of Cardiovascular Magnetic Resonance, Vol: 16, Pages: 1-16, ISSN: 1097-6647

BackgroundCardiac diffusion tensor imaging (cDTI) measures the magnitudes and directions of intramyocardial water diffusion. Assuming the cross-myocyte components to be constrained by the laminar microstructures of myocardium, we hypothesized that cDTI at two cardiac phases might identify any abnormalities of laminar orientation and mobility in hypertrophic cardiomyopathy (HCM).MethodsWe performed cDTI in vivo at 3 Tesla at end-systole and late diastole in 11 healthy controls and 11 patients with HCM, as well as late gadolinium enhancement (LGE) for detection of regional fibrosis.ResultsVoxel-wise analysis of diffusion tensors relative to left ventricular coordinates showed expected transmural changes of myocardial helix-angle, with no significant differences between phases or between HCM and control groups. In controls, the angle of the second eigenvector of diffusion (E2A) relative to the local wall tangent plane was larger in systole than diastole, in accord with previously reported changes of laminar orientation. HCM hearts showed higher than normal global E2A in systole (63.9° vs 56.4° controls, p =0.026) and markedly raised E2A in diastole (46.8° vs 24.0° controls, p < 0.001). In hypertrophic regions, E2A retained a high, systole-like angulation even in diastole, independent of LGE, while regions of normal wall thickness did not (LGE present 57.8°, p =0.0028, LGE absent 54.8°, p =0.0022 vs normal thickness 38.1°).ConclusionsIn healthy controls, the angles of cross-myocyte components of diffusion were consistent with previously reported transmural orientations of laminar microstructures and their changes with contraction. In HCM, especially in hypertrophic regions, they were consistent with hypercontraction in systole and failure of relaxation in diastole. Further investigation of this finding is required as previously postulated effects of strain might be a confounding factor.

Journal article

Ambrose N, Pierce IT, Gatehouse PD, Haskard DO, Firmin DNet al., 2014, Magnetic resonance imaging of vein wall thickness in patients with Behcet's syndrome, CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, Vol: 32, Pages: S99-S102, ISSN: 0392-856X

Journal article

Simpson R, Keegan J, Gatehouse P, Hansen M, Firmin Det al., 2014, Spiral Tissue Phase Velocity Mapping in a Breath-Hold with Non-Cartesian SENSE, MAGNETIC RESONANCE IN MEDICINE, Vol: 72, Pages: 659-668, ISSN: 0740-3194

Journal article

Nielles-Vallespin S, Mekkaoui C, Gatehouse P, Reese TG, Keegan J, Ferreira PF, Collins S, Speier P, Feiweier T, de Silva R, Jackowski MP, Pennell DJ, Sosnovik DE, Firmin Det al., 2014, In Vivo Diffusion Tensor MRI of the Human Heart: Reproducibility of Breath-Hold and Navigator Based Approaches (vol 70, pg 454, 2013), MAGNETIC RESONANCE IN MEDICINE, Vol: 72, Pages: 599-599, ISSN: 0740-3194

Journal article

Simpson R, Keegan J, Gatehouse P, Hansen M, Firmin Det al., 2014, Accelerating spiral tissue phase velocity mapping without affecting peak velocity measurements, Journal of Cardiovascular Magnetic Resonance, Vol: 16, ISSN: 1097-6647

Journal article

Ali A, Hsu LY, Gulati A, Ismail T, Raphael CE, Vassiliou V, Chahal N, Krishnathansan K, Davendralingam N, Goncalves C, Wage R, Ferreira P, Baksi AJ, Gatehouse P, Firmin D, Pennell DJ, Kellman P, Arai AE, Prasad SKet al., 2014, The association between ECV and microcirculation perfusion abnormalities in non-ischemic dilated cardiomyopathy, Journal of Cardiovascular Magnetic Resonance, Vol: 16, ISSN: 1097-6647

Journal article

Heng EL, Vassiliou V, Gatehouse P, Greiser A, Giri S, Donovan J, Babu-Narayan SV, Gatzoulis MA, Pennell DJ, Prasad SK, Firmin Det al., 2014, Temporal stability of gel relaxation-time phantoms for quality control of T1 and extracellular volume fraction measurements, Journal of Cardiovascular Magnetic Resonance, Vol: 16, Pages: P60-P60, ISSN: 1097-6647

Journal article

Keegan J, Gatehouse P, Haldar S, Wage R, Babu-Narayan SV, Firmin Det al., 2014, Improved 3D late gadolinium enhancement (LGE) imaging with dynamic-TI in patients with persistent atrial fibrillation, Journal of Cardiovascular Magnetic Resonance, Vol: 16, Pages: P6-P6, ISSN: 1097-6647

Journal article

Simpson R, Keegan J, Gatehouse P, Hansen M, Firmin Det al., 2014, Breath-hold spiral tissue phase velocity mapping (TPVM) with non-Cartesian SENSE, Journal of Cardiovascular Magnetic Resonance, Vol: 16, Pages: P40-P40, ISSN: 1097-6647

Journal article

Fair M, Gatehouse P, Drivas P, Alpendurada F, Firmin Det al., 2014, Method for correcting respiratory artefacts in parallel-accelerated first-pass myocardial perfusion imaging, Journal of Cardiovascular Magnetic Resonance, Vol: 16, Pages: P58-P58, ISSN: 1097-6647

Journal article

Ismail TF, Hsu L-Y, Greve AM, Gonçalves C, Jabbour A, Gulati A, Hewins B, Mistry N, Wage R, Roughton M, otherset al., 2014, Coronary microvascular ischemia in hypertrophic cardiomyopathy-a pixel-wise quantitative cardiovascular magnetic resonance perfusion study, Journal of Cardiovascular Magnetic Resonance, Vol: 16, Pages: 49-49

Journal article

Ferreira P, Kilner PJ, McGill L-A, Nielles-Vallespin S, Scott AD, Spottiswoode BS, Zhong X, Ho SY, McCarthy K, Ismail T, otherset al., 2014, Aberrant myocardial sheetlet mobility in hypertrophic cardiomyopathy detected using in vivo cardiovascular magnetic resonance diffusion tensor imaging, Journal of Cardiovascular Magnetic Resonance, Vol: 16, Pages: P338-P338

Journal article

Feng Y, He T, Gatehouse PD, Li X, Harith Alam M, Pennell DJ, Chen W, Firmin DNet al., 2013, Improved MRI <i>R</i><sub>2</sub>* Relaxometry of Iron-Loaded Liver with Noise Correction, MAGNETIC RESONANCE IN MEDICINE, Vol: 70, Pages: 1765-1774, ISSN: 0740-3194

Journal article

Moon JC, Messroghli DR, Kellman P, Piechnik SK, Robson MD, Ugander M, Gatehouse PD, Arai AE, Friedrich MG, Neubauer S, Schulz-Menger J, Schelbert EBet al., 2013, Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement, JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, Vol: 15, ISSN: 1097-6647

Journal article

Feng Y, He T, Carpenter J-P, Jabbour A, Alam MH, Gatehouse PD, Greiser A, Messroghli D, Firmin DN, Pennell DJet al., 2013, In vivo comparison of myocardial T1 with T2 and T2*in thalassaemia major, JOURNAL OF MAGNETIC RESONANCE IMAGING, Vol: 38, Pages: 588-593, ISSN: 1053-1807

Journal article

McGill L-A, Ismail T, Nielles-Vallespin S, Ferreira P, Scott AD, Roughton M, Kilner PJ, Ho SY, McCarthy KP, Gatehouse PD, de Silva R, Speier P, Feiweier T, Mekkaoui C, Sosnovik DE, Prasad SK, Firmin DN, Pennell DJet al., 2013, reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy (vol 14, pg 86, 2012), JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, Vol: 15, ISSN: 1097-6647

Journal article

Fair M, Gatehouse PD, Greiser A, Drivas P, Firmin DNet al., 2013, A novel approach to phase-contrast velocity offset correction by in vivo high-SNR acquisitions, Society for Cardiovascular Magnetic Resonance, Publisher: BioMed Central, ISSN: 1532-429X

Baseline offset errors on phase-contrast velocity imagescan be corrected using stationary tissue, for example sub-tracting fitted corrections from the image (1). Althoughcorrections are often curved over the FOV, 1st order(linear) fitting is typical. This may partly be due to lowSNR of static tissue making higher-order fitting unreli-able (2). Aim: To evaluate a new method acquiring addi-tional high SNR velocity images specifically to improveoffset correction.

Conference paper

Mekkaoui C, Nielles-Vallespin S, Jackowski MP, Gatehouse PD, Pennell DJ, Firmin DN, Sosnovik DEet al., 2013, Improving the accuracy of multi breath-hold diffusion tensor MRI tractography of the heart using dynamic motioncorrection, Journal of Cardiovascular Magnetic Resonance, Vol: 15, ISSN: 1097-6647

Journal article

Ismail TF, Jabbour A, Gulati A, Mistry N, Abdel-Malek M, Hewins B, Wage R, Roughton M, Ferreira PF, Gatehouse PD, Firmin DN, Pennell DJ, Kellman P, Prasad SKet al., 2013, Role of T1 and T2-mapping in assessing the myocardial interstitium in hypertrophic cardiomyopathy: a cardiovascular magnetic resonance study, Journal of Cardiovascular Magnetic Resonance, Vol: 15, ISSN: 1097-6647

Journal article

This data is extracted from the Web of Science and reproduced under a licence from Thomson Reuters. You may not copy or re-distribute this data in whole or in part without the written consent of the Science business of Thomson Reuters.

Request URL: http://wlsprd.imperial.ac.uk:80/respub/WEB-INF/jsp/search-html.jsp Request URI: /respub/WEB-INF/jsp/search-html.jsp Query String: id=00426135&limit=30&person=true&page=3&respub-action=search.html