Imperial College London

ProfessorRogerKneebone

Faculty of MedicineDepartment of Surgery & Cancer

Professor of Surgical Education and Engagement Science
 
 
 
//

Contact

 

r.kneebone Website

 
 
//

Location

 

ICCESS, Academic SurgeryChelsea and Westminster HospitalChelsea and Westminster Campus

//

Summary

 

Publications

Citation

BibTex format

@article{Granados:2020:10.1109/TBME.2020.2971826,
author = {Granados, A and Cox, S and Low-Beer, N and Higham, J and Kneebone, R and Bello, F},
doi = {10.1109/TBME.2020.2971826},
journal = {IEEE Transactions on Biomedical Engineering},
pages = {2798--2805},
title = {Taking the pressure off the patient - understanding digital rectal examinations on a real subject},
url = {http://dx.doi.org/10.1109/TBME.2020.2971826},
volume = {67},
year = {2020}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - Better understanding of palpation techniques during unsighted physical examinations has mostly been limited to qualitative and quantitative studies of performance of experts whilst conducting examinations on plastic benchtop models. However, little is known about their performance when conducting such examinations on real subjects. OBJECTIVE: The aim of this paper is to better understand palpation techniques of experts whilst conducting a Digital Rectal Examination on a real subject. METHODS: We recruited four consultants from relevant specialties and asked them to conduct two DREs on a Rectal Teaching Assistant whilst wearing small position and pressure sensors on their examining finger. We segmented the relevant anatomy from an MRI taken of the pelvic region, registered 3D models and analysed retrospectively performance in relation to executed tasks, supination/pronation, palpation convex hull and pressure applied. RESULTS: Primary care consultants examined the anatomy more holistically compared to secondary care experts, the maximum pressure applied across experiments is 3.3N, overall the pressure applied on the prostate is higher than that applied to rectal walls, and the urologist participant not only applied the highest pressure but also did so with the highest most prominent frequency (15.4 and 25.3 Hz). CONCLUSIONS: The results of our research allow for better understanding of experts' technical performance from relevant specialities when conducting a DRE, and suggest the range of pressure applied whilst palpating anatomy. SIGNIFICANCE: This research will be valuable in improving the design of haptics-based learning tools, as well as in encouraging reflection on palpation styles across different specialities to develop metrics of performance.
AU - Granados,A
AU - Cox,S
AU - Low-Beer,N
AU - Higham,J
AU - Kneebone,R
AU - Bello,F
DO - 10.1109/TBME.2020.2971826
EP - 2805
PY - 2020///
SN - 0018-9294
SP - 2798
TI - Taking the pressure off the patient - understanding digital rectal examinations on a real subject
T2 - IEEE Transactions on Biomedical Engineering
UR - http://dx.doi.org/10.1109/TBME.2020.2971826
UR - https://www.ncbi.nlm.nih.gov/pubmed/32031926
UR - https://ieeexplore.ieee.org/document/8984327
UR - http://hdl.handle.net/10044/1/76730
VL - 67
ER -