Imperial College London

ProfessorStevenRose

Faculty of Natural SciencesDepartment of Physics

Senior Research Investigator
 
 
 
//

Contact

 

+44 (0)20 7594 7635s.rose Website

 
 
//

Location

 

728Blackett LaboratorySouth Kensington Campus

//

Summary

 

Publications

Citation

BibTex format

@inproceedings{Nilsen:2019:10.1117/12.2528884,
author = {Nilsen, J and Burridge, D and Hobbs, LMR and Hoarty, D and Beiersdorfer, P and Brown, GV and Hell, N and Panchenko, D and Gu, MF and Saunders, AM and Scott, HA and London, RA and Hatfield, P and Hill, MP and Wilson, L and Charles, R and Brown, CRD and Rose, S},
doi = {10.1117/12.2528884},
pages = {1111105--1--1111105--6},
publisher = {SPIE},
title = {Enhanced fluorescence from x-ray line coincidence pumping of K-pumped Cl and Mg-pumped Ge plasmas},
url = {http://dx.doi.org/10.1117/12.2528884},
year = {2019}
}

RIS format (EndNote, RefMan)

TY  - CPAPER
AB - Many resonant photo-pumped X-ray laser schemes that use a strong pump line such as Ly-α or He-α to populate the upper laser state of a separate lasing material have been proposed over the last four decades but none have been demonstrated. As a first step to creating a photo-pumped X-ray laser we decided to reinvestigate some of these schemes at the Orion laser facility with the goal to demonstrate enhanced fluorescence as a first step toward creating a laser. In particular we look at using the Ly-α or He-α K lines to pump the 1s – 3p and 4p transitions in H-like Cl and see fluorescence on the 4f -3d line at 65 Å and the 3d – 2p line at 23 Å. Preliminary experiments are presented that show a modest enhancement of 40% on the 3d-2p line. As an alternative we also look at enhancing the 2p – 2s line in Ne-like Ge at 65Å using the Ly-α Mg line to photo-pump the 2s – 3p line of Ne-like Ge. Calculations are presented that suggest modest enhancements of 2.5 and recent experiments will be presented that show emission from a Ge plasma pumped by the Ly-α Mg line.
AU - Nilsen,J
AU - Burridge,D
AU - Hobbs,LMR
AU - Hoarty,D
AU - Beiersdorfer,P
AU - Brown,GV
AU - Hell,N
AU - Panchenko,D
AU - Gu,MF
AU - Saunders,AM
AU - Scott,HA
AU - London,RA
AU - Hatfield,P
AU - Hill,MP
AU - Wilson,L
AU - Charles,R
AU - Brown,CRD
AU - Rose,S
DO - 10.1117/12.2528884
EP - 1
PB - SPIE
PY - 2019///
SP - 1111105
TI - Enhanced fluorescence from x-ray line coincidence pumping of K-pumped Cl and Mg-pumped Ge plasmas
UR - http://dx.doi.org/10.1117/12.2528884
UR - https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11111/2528884/Enhanced-fluorescence-from-x-ray-line-coincidence-pumping-of-K/10.1117/12.2528884.full?SSO=1
UR - http://hdl.handle.net/10044/1/74578
ER -