@article{Sirunyan:2017:04/P04023,
author = {Sirunyan, AM and Tumasyan, A and Adam, W and Asilar, E and Bergauer, T and Brandstetter, J and Brondolin, E and Dragicevic, M and Eroe, J and Flechl, M and Friedl, M and Fruehwirth, R and Ghete, VM and Hoch, M and Hartl, C and Hoermann, N and Hrubec, J and Jeitler, M and Koenig, A and Kraetschmer, I and Liko, D and Matsushita, T and Mikulec, I and Rabady, D and Rad, N and Rahbaran, B and Rohringer, H and Schieck, J and Strauss, J and Waltenberger, W and Wulz, C-E and Dvornikov, O and Makarenko, V and Mossolov, V and Gonzalez, JS and Zykunov, V and Shumeiko, N and Alderweireldt, S and De, Wolf EA and Janssen, X and Lauwers, J and De, Klundert MV and Van, Haevermaet H and Van, Mechelen P and Van, Remortel N and Van, Spilbeeck A and Abu, Zeid S and Blekman, F and D'Hondt, J and Daci, N and De, Bruyn I and Deroover, K and Lowette, S and Moortgat, S and Moreels, L and Olbrechts, A and Python, Q and Skovpen, K and Tavernier, S and Van, Doninck W and Van, Mulders P and Van, Parijs I and Brun,},
doi = {04/P04023},
journal = {Journal of Instrumentation},
title = {Mechanical stability of the CMS strip tracker measured with a laser alignment system},
url = {http://dx.doi.org/10.1088/1748-0221/12/04/P04023},
volume = {12},
year = {2017}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - The CMS tracker consists of 206 m2 of silicon strip sensors assembled on carbon fibrecomposite structures and is designed for operation in the temperature range from −25 to +25C.The mechanical stability of tracker components during physics operation was monitored with afew µm resolution using a dedicated laser alignment system as well as particle tracks from cosmicrays and hadron-hadron collisions. During the LHC operational period of 2011–2013 at stabletemperatures, the components of the tracker were observed to experience relative movements ofless than 30 µm. In addition, temperature variations were found to cause displacements of trackerstructures of about 2 µm/C, which largely revert to their initial positions when the temperature isrestored to its original value.
AU - Sirunyan,AM
AU - Tumasyan,A
AU - Adam,W
AU - Asilar,E
AU - Bergauer,T
AU - Brandstetter,J
AU - Brondolin,E
AU - Dragicevic,M
AU - Eroe,J
AU - Flechl,M
AU - Friedl,M
AU - Fruehwirth,R
AU - Ghete,VM
AU - Hoch,M
AU - Hartl,C
AU - Hoermann,N
AU - Hrubec,J
AU - Jeitler,M
AU - Koenig,A
AU - Kraetschmer,I
AU - Liko,D
AU - Matsushita,T
AU - Mikulec,I
AU - Rabady,D
AU - Rad,N
AU - Rahbaran,B
AU - Rohringer,H
AU - Schieck,J
AU - Strauss,J
AU - Waltenberger,W
AU - Wulz,C-E
AU - Dvornikov,O
AU - Makarenko,V
AU - Mossolov,V
AU - Gonzalez,JS
AU - Zykunov,V
AU - Shumeiko,N
AU - Alderweireldt,S
AU - De,Wolf EA
AU - Janssen,X
AU - Lauwers,J
AU - De,Klundert MV
AU - Van,Haevermaet H
AU - Van,Mechelen P
AU - Van,Remortel N
AU - Van,Spilbeeck A
AU - Abu,Zeid S
AU - Blekman,F
AU - D'Hondt,J
AU - Daci,N
AU - De,Bruyn I
AU - Deroover,K
AU - Lowette,S
AU - Moortgat,S
AU - Moreels,L
AU - Olbrechts,A
AU - Python,Q
AU - Skovpen,K
AU - Tavernier,S
AU - Van,Doninck W
AU - Van,Mulders P
AU - Van,Parijs I
AU - Brun,H
AU - Clerbaux,B
AU - De,Lentdecker G
AU - Delannoy,H
AU - Fasanella,G
AU - Favart,L
AU - Goldouzian,R
AU - Grebenyuk,A
AU - Karapostoli,G
AU - Lenzi,T
AU - Leonard,A
AU - Luetic,J
AU - Maerschalk,T
AU - Marinov,A
AU - Randle-conde,A
AU - Seva,T
AU - Velde,CV
AU - Vanlaer,P
AU - Vannerom,D
AU - Yonamine,R
AU - Zenoni,F
AU - Zhang,F
AU - Cimmino,A
AU - Cornelis,T
AU - Dobur,D
AU - Fagot,A
AU - Gul,M
AU - Khvastunov,I
AU - Poyraz,D
AU - Salva,S
AU - Schofbeck,R
AU - Tytgat,M
AU - Van,Driessche W
AU - Yazgan,E
AU - Zaganidis,N
AU - Bakhshiansohi,H
AU - Beluffi,C
AU - Bondu,O
AU - Brochet,S
AU - Bruno,G
AU - Caudron,A
AU - De,Visscher S
AU - Delaere,C
AU - Delcourt,M
AU - Francois,B
AU - Giammanco,A
AU - Jafari,A
AU - Komm,M
AU - Krintiras,G
AU - Lemaitre,V
AU - Magitteri,A
AU - Mertens,A
AU - Musich,M
AU - Piotrzkowski,K
AU - Quertenmont,L
AU - Selvaggi,M
AU - Marono,MV
AU - Wertz,S
AU - Beliy,N
AU - Alda,Junior WL
AU - Alves,FL
AU - Alves,GA
AU - Brito,L
AU - Hensel,C
AU - Moraes,A
AU - Pol,ME
AU - Rebello,Teles P
AU - Belchior,Batista Das Chagas E
AU - Carvalho,W
AU - Chinellato,J
AU - Custodio,A
AU - Da,Costa EM
AU - Da,Silveira GG
AU - De,Jesus Damiao D
AU - De,Oliveira Martins C
AU - Fonseca,De Souza S
AU - Huertas,Guativa LM
AU - Malbouisson,H
AU - Matos,Figueiredo D
AU - Mora,Herrera C
AU - Mundim,L
AU - Nogima,H
AU - Prado,Da Silva WL
AU - Santoro,A
AU - Sznajder,A
AU - Tonelli,Manganote EJ
AU - Torres,Da Silva De Araujo F
AU - Vilela,Pereira A
AU - Ahuja,S
AU - Bernardes,CA
AU - Dogra,S
AU - Fernandez,Perez Tomei TR
AU - Gregores,EM
AU - Mercadante,PG
AU - Moon,CS
AU - Novaes,SF
AU - Padula,SS
AU - Rom
DO - 04/P04023
PY - 2017///
SN - 1748-0221
TI - Mechanical stability of the CMS strip tracker measured with a laser alignment system
T2 - Journal of Instrumentation
UR - http://dx.doi.org/10.1088/1748-0221/12/04/P04023
UR - http://hdl.handle.net/10044/1/53245
VL - 12
ER -