BibTex format
@article{Koutsoftidis:2022:10.1109/TBME.2022.3170025,
author = {Koutsoftidis, S and Barsakcioglu, DY and Petkos, K and Farina, D and Drakakis, E},
doi = {10.1109/TBME.2022.3170025},
journal = {IEEE Transactions on Biomedical Engineering},
pages = {3389--3396},
title = {Myolink: a 128-channel, 18 nV/√Hz, embedded recording system, optimized for high-density surface electromyogram acquisition},
url = {http://dx.doi.org/10.1109/TBME.2022.3170025},
volume = {69},
year = {2022}
}
RIS format (EndNote, RefMan)
TY - JOUR
AB - Objective: We present Myolink, a portable, modular, low-noise electrophysiology amplifier optimized for high-density surface electromyogram (HD sEMG) acquisition. Methods: Myolink consists of 4 modules. Each 10 × 8 cm module can concurrently acquire 32 unipolar electrode potentials at sampling rates of up to 8 kHz with 24-bit resolution. Modules may be stacked and operated synchronously, supporting the concurrent acquisition of up to 128 channels. A custom high-performance analog front-end provides an input-referred-noise <0.4 μVRMS for a bandwidth of 23–524 Hz (tuneable by design choices), which is lower than current commercial systems. Digitized signals are processed by a custom on-board FPGA-based controller and subsequently transmitted to a PC via a medical-grade isolated USB 2.0 interface. Results: The system has been tested by recording experimental HD sEMG signals, which have been subsequently decomposed into motor unit action potentials. Compared to commercially available systems, the proposed recording system led to higher-quality surface EMG acquisition, as well as higher decomposition accuracy across a wide range of forces, with the greater gain for forces ≤ 20% of the maximum voluntary contraction. Significance: A portable, ultra-low-noise, HD sEMG amplifier design has been implemented and characterized. The system provides IRN performance beyond the capabilities of current state-of-the-art instrumentation and this improvement has a significant effect on HD sEMG decomposition.
AU - Koutsoftidis,S
AU - Barsakcioglu,DY
AU - Petkos,K
AU - Farina,D
AU - Drakakis,E
DO - 10.1109/TBME.2022.3170025
EP - 3396
PY - 2022///
SN - 0018-9294
SP - 3389
TI - Myolink: a 128-channel, 18 nV/√Hz, embedded recording system, optimized for high-density surface electromyogram acquisition
T2 - IEEE Transactions on Biomedical Engineering
UR - http://dx.doi.org/10.1109/TBME.2022.3170025
UR - https://ieeexplore.ieee.org/document/9762559
VL - 69
ER -