Citation

BibTex format

@article{Abel:2025:epjc/s10052-025-13902-x,
author = {Abel, C and Ayres, NJ and Ban, G and Bison, G and Bodek, K and Bondar, V and Bouillaud, T and Bowles, DC and Caratsch, GL and Chanel, E and Chen, W and Chiu, P-J and Crawford, C and Dechenaux, B and Doorenbos, CB and Emmenegger, S and Ferraris-Bouchez, L and Fertl, M and Flaux, P and Fratangelo, A and Goupillière, D and Griffith, WC and Grujic, Z and Höhl, D and Kasprzak, M and Kirch, K and Kletzl, V and Komposch, SV and Koss, PA and Krempel, J and Lauss, B and Lefort, T and Lejuez, A and Li, R and Meier, M and Menu, J and Michielsen, K and Mullan, P and Mullins, A and Naviliat-Cuncic, O and Pais, D and Piegsa, FM and Pignol, G and Quemener, G and Rawlik, M and Rebreyend, D and Rienaecker, I and Ries, D and Roccia, S and Rozpedzik, D and Schnabel, A and Schmidt-Wellenburg, P and Segarra, EP and Severijns, N and Smith, CA and Svirina, K and Tavakoli, R and Thorne, J and Touati, S and Vankeirsbilck, J and Virot, R and Voigt, J and Wursten, E and Yazdandoost, N and Zejma, J and Ziehl, N a},
doi = {epjc/s10052-025-13902-x},
journal = {Eur Phys J C Part Fields},
title = {Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment.},
url = {http://dx.doi.org/10.1140/epjc/s10052-025-13902-x},
volume = {85},
year = {2025}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main B 0 coil and a set of auxiliary coils mounted on a cubic structure with a side length of 273 cm , inside a large magnetically shielded room (MSR). We have assembled this system and characterized its performances with a mapping robot. The apparatus is able to generate a 1 μ T vertical field with a relative root mean square deviation σ ( B z ) / B z = 3 × 10 - 5 over the volume of interest, a cylinder of radius 40 cm and height 30 cm . This level of uniformity overcomes the n2EDM requirements, allowing a measurement of the neutron Electric Dipole Moment with a sensitivity better than 1 × 10 - 27 e cm .
AU - Abel,C
AU - Ayres,NJ
AU - Ban,G
AU - Bison,G
AU - Bodek,K
AU - Bondar,V
AU - Bouillaud,T
AU - Bowles,DC
AU - Caratsch,GL
AU - Chanel,E
AU - Chen,W
AU - Chiu,P-J
AU - Crawford,C
AU - Dechenaux,B
AU - Doorenbos,CB
AU - Emmenegger,S
AU - Ferraris-Bouchez,L
AU - Fertl,M
AU - Flaux,P
AU - Fratangelo,A
AU - Goupillière,D
AU - Griffith,WC
AU - Grujic,Z
AU - Höhl,D
AU - Kasprzak,M
AU - Kirch,K
AU - Kletzl,V
AU - Komposch,SV
AU - Koss,PA
AU - Krempel,J
AU - Lauss,B
AU - Lefort,T
AU - Lejuez,A
AU - Li,R
AU - Meier,M
AU - Menu,J
AU - Michielsen,K
AU - Mullan,P
AU - Mullins,A
AU - Naviliat-Cuncic,O
AU - Pais,D
AU - Piegsa,FM
AU - Pignol,G
AU - Quemener,G
AU - Rawlik,M
AU - Rebreyend,D
AU - Rienaecker,I
AU - Ries,D
AU - Roccia,S
AU - Rozpedzik,D
AU - Schnabel,A
AU - Schmidt-Wellenburg,P
AU - Segarra,EP
AU - Severijns,N
AU - Smith,CA
AU - Svirina,K
AU - Tavakoli,R
AU - Thorne,J
AU - Touati,S
AU - Vankeirsbilck,J
AU - Virot,R
AU - Voigt,J
AU - Wursten,E
AU - Yazdandoost,N
AU - Zejma,J
AU - Ziehl,N
AU - Zsigmond,G
DO - epjc/s10052-025-13902-x
PY - 2025///
SN - 1434-6044
TI - Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment.
T2 - Eur Phys J C Part Fields
UR - http://dx.doi.org/10.1140/epjc/s10052-025-13902-x
UR - https://www.ncbi.nlm.nih.gov/pubmed/39989896
VL - 85
ER -