AB - This paper investigates robustness of permanently mounted transducers used in airbornestructural health monitoring systems, when exposed to the operational environment. Typicalairliners operate in a range of conditions, hence SHM transducer robustness and integrity mustbe demonstrated for these environments. A set of extreme temperature, altitude and vibrationenvironment test profiles are developed using the existing RTCA/DO-160 test methods. Commerciallyavailable transducers and manufactured versions bonded to CFRP composite materials are tested. Itwas found that the DuraAct transducer is robust to environmental conditions tested, while the othertransducer types degrade under the same conditions.