The MIM Lab develops robotic and mechatronics surgical systems for a variety of procedures.

Head of Group

Prof Ferdinando Rodriguez y Baena

B415C Bessemer Building
South Kensington Campus

+44 (0)20 7594 7046

⇒ X: @fmryb

 

What we do

The Mechatronics in Medicine Laboratory develops robotic and mechatronics surgical systems for a variety of procedures including neuro, cardiovascular, orthopaedic surgeries, and colonoscopies. Examples include bio-inspired catheters that can navigate along complex paths within the brain (such as EDEN2020), soft robots to explore endoluminal anatomies (such as the colon), and virtual reality solutions to support surgeons during knee replacement surgeries.

Why is it important

The integration of mechatronics into medicine addresses critical challenges in modern healthcare by enhancing the precision, safety, and efficiency of surgical procedures. Traditional surgeries often involve significant risks and extended recovery times. By developing robotic systems that offer greater accuracy and control, we aim to minimise these risks and reduce invasiveness. Our research contributes to the advancement of minimally invasive techniques, which are essential for improving patient outcomes and optimising healthcare resources. Furthermore, our work supports the training of the next generation of surgeons, equipping them with cutting-edge tools and methodologies that reflect the evolving landscape of medical technology.

How can it benefit patients

Patients stand to gain significantly from the innovations developed at the Mechatronics in Medicine Laboratory. Our robotic systems are designed to perform surgeries with enhanced precision, leading to fewer complications and faster recovery times. Minimally invasive procedures facilitated by our technologies result in less postoperative pain and reduced scarring, improving the overall patient experience. Additionally, the increased accuracy of our systems can lead to better surgical outcomes, such as more complete tumour removals or more precise joint replacements, thereby improving long-term health prospects. By pushing the boundaries of medical robotics, we strive to make advanced surgical care more accessible and effective for patients worldwide.

Meet the team

Citation

BibTex format

@article{Virdyawan:2018:1748-3190/aaa6f4,
author = {Virdyawan, V and Rodriguez, y Baena F and Oldfield, M},
doi = {1748-3190/aaa6f4},
journal = {Bioinspiration and Biomimetics},
title = {Laser Doppler sensing for blood vessel detection with a biologically inspired steerable needle},
url = {http://dx.doi.org/10.1088/1748-3190/aaa6f4},
volume = {13},
year = {2018}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - Puncturing blood vessels during percutaneous intervention in minimally invasive brain surgery can be a life threatening complication. Embedding a forward looking sensor in a rigid needle has been proposed to tackle this problem but, when using a rigid needle, the procedure needs to be interrupted and the needle extracted if a vessel is detected. As an alternative, we propose a novel optical method to detect a vessel in front of a steerable needle. The needle itself is based on a biomimetic, multi-segment design featuring four hollow working channels. Initially, a laser Doppler flowmetry probe is characterized in a tissue phantom with optical properties mimicking those of human gray matter. Experiments are performed to show that the probe has a 2.1 mm penetration depth and a 1 mm off-axis detection range for a blood vessel phantom with 5 mm/s flow velocity. This outcome demonstrates that the probe fulfills the minimum requirements for it to be used in conjunction with our needle. A pair of Doppler probes is then embedded in two of the four working channels of the needle and vessel reconstruction is performed using successive measurements to determine the depth and the off-axis position of the vessel from each laser Doppler probe. The off-axis position from each Doppler probe is then used to generate a "detection circle" per probe, and vessel orientation is predicted using tangent lines between the two. The vessel reconstruction has a depth Root Mean Square Error (RMSE) of 0.3 mm and an RMSE of 15° in the angular prediction, showing real promise for a future clinical application of this detection system.
AU - Virdyawan,V
AU - Rodriguez,y Baena F
AU - Oldfield,M
DO - 1748-3190/aaa6f4
PY - 2018///
SN - 1748-3182
TI - Laser Doppler sensing for blood vessel detection with a biologically inspired steerable needle
T2 - Bioinspiration and Biomimetics
UR - http://dx.doi.org/10.1088/1748-3190/aaa6f4
VL - 13
ER -

Contact Us

General enquiries

Facility enquiries


The Hamlyn Centre
Bessemer Building
South Kensington Campus
Imperial College
London, SW7 2AZ
Map location